.:dmtccnc:home

From ADPAA
Jump to navigation Jump to search

process_raw (Level 2)

Purpose

Extracts *.serialc.dmtccnc.raw and *.serialh.dmtccnc.raw from SEA M300 data system file (*.sea).

Required Input Files

*.sea

Output Files

*.serialc.dmtccnc.raw

*.serialh.dmtccnc.raw

dmtccnc2stp (Level 4)

Purpose

Determines the Droplete Measurement Technologies (DMT) Cloud Concentration Nuclei (CCN) Counter concentration at ambient pressure and temperature, and at standard pressure and temperature.

Required Input Files

*.serialc.dmtccnc.raw

*.serialh.dmtccnc.raw

Optional Input Files

*.basic.1Hz (Provides temperature measurement.)

*.physical.1Hz (Provides pressure measurement.)

Note: If physical and basic files not provided, ambient conc can not be calculated.

Output Files

*.dmtccn_conc.raw