.rosemounttemp:M300: Difference between revisions
Davidjdelene (talk | contribs) No edit summary |
Davidjdelene (talk | contribs) No edit summary |
||
Line 6: | Line 6: | ||
''Purpose'' | ''Purpose'' | ||
Select either Analog or CIP data from static and dynamic pressure measurements. | Select either Analog or CIP data from static and dynamic pressure measurements in the *.physical.* file. | ||
''Default'' | ''Default'' | ||
Analog data | Analog data | ||
=Primitive Data Processing Scripts= | =Primitive Data Processing Scripts= |
Revision as of 18:04, 13 March 2015
Rosemount Temperature Probe (Aircraft Processing)
Master Data Processing Scripts
process_all
Purpose
Select either Analog or CIP data from static and dynamic pressure measurements in the *.physical.* file.
Default
Analog data
Primitive Data Processing Scripts
process_raw
Purpose
Extracts analog data from SEA M300 data system file (*.sea) and creates the *.analog.raw file. Extracts Cloud Imaging Probes (CIP) housekeeping information from SEA M300 data system file(*.sea).
Required Input File
*.sea
Output File
*.analog.raw *.housekeeping.cip.raw
analog2physical
Purpose
To convert analog measurements from engineering units (voltages) to physical units (i.e. degree C).
Required Input File
*.analog.*
Output File
*.physical.*
convert_physical
Purpose
Uses total temperature, static pressure and dynamic pressure to correct for dynamic effect on the total temperature measurement to calculate air temperature.
Required Input File
*.physical.*
Output File
*.basic.raw
Processing Reference
Rosemount Manual