.tdlhygrometer: Difference between revisions

From ADPAA
Jump to navigation Jump to search
 
(5 intermediate revisions by 2 users not shown)
Line 1: Line 1:
Tunable Laser Diode (TDL) Hygrometer Processing
Tunable Laser Diode (TDL) Hygrometer Processing
University of Wyoming (UWyo) Cloud Condensation Nuclei Counter -- M200 Data System Processing


==process_raw (Level 1)==
==process_raw (Level 1)==
Line 7: Line 5:
'''Purpose'''
'''Purpose'''


Extracts *.analog.raw from data acquisition system file (*.sea).
Extracts *.analog.raw from the data acquisition system file (*.sea).


'''Required Input Files'''
'''Required Input Files'''
Line 27: Line 25:
<nowiki>*.analog.raw</nowiki>
<nowiki>*.analog.raw</nowiki>
        
        
Note:  If physical and basic files not provided, ambient conc can not be calculated.
Note:  If physical and basic files are not provided, the ambient concentration can not be calculated.


'''Output Files'''
'''Output Files'''
<nowiki>*.ccn.raw</nowiki>
==convert_physical (Level 3)==
'''Purpose'''
Creates Level 3 parameters from the physical file.
'''Required Input Files'''


<nowiki>*.physical.raw</nowiki>
<nowiki>*.physical.raw</nowiki>


'''Output Files'''
<nowiki>*.TLDflow.raw</nowiki>
 
<nowiki>*.basic.*</nowiki>
 
<nowiki>*.egg.raw</nowiki>


==winds_file (Level 3)==
==tdl2humidity (Level 3)==


'''Purpose'''
'''Purpose'''


Calculates the 3-D wind vectors based on pitot nose data and position data from the Applanix system.
Calculates TDL humidity parameters


'''Required Input Files'''
'''Required Input Files'''


<nowiki>*.physical.raw</nowiki>
<nowiki>*.wind.raw</nowiki> ''OR'' *.basic.raw


<nowiki>*.applanix.raw</nowiki> ''or'' *.SBET.raw
<nowiki>*.serial.tdl.*</nowiki> ''OR'' *.tdl.* ''AND'' *.physical.raw


'''Output Files'''
'''Output Files'''


<nowiki>*.winds.raw</nowiki>
<nowiki>*.hum.raw</nowiki>
 
<nowiki>*.egg.raw</nowiki>

Latest revision as of 20:34, 8 August 2018

Tunable Laser Diode (TDL) Hygrometer Processing

process_raw (Level 1)

Purpose

Extracts *.analog.raw from the data acquisition system file (*.sea).

Required Input Files

*.sea

Output Files

*.analog.raw

analog2physical (Level 2)

Purpose

Converts from voltage to physical units.

Required Input Files

*.analog.raw

Note: If physical and basic files are not provided, the ambient concentration can not be calculated.

Output Files

*.physical.raw

*.TLDflow.raw

tdl2humidity (Level 3)

Purpose

Calculates TDL humidity parameters

Required Input Files

*.wind.raw OR *.basic.raw

*.serial.tdl.* OR *.tdl.* AND *.physical.raw

Output Files

*.hum.raw