.rosemounttemp:M300: Difference between revisions
Davidjdelene (talk | contribs) No edit summary |
Daviddelene (talk | contribs) |
||
(One intermediate revision by one other user not shown) | |||
Line 1: | Line 1: | ||
Rosemount Temperature Probe | Rosemount Temperature Probe -- Aircraft Processing | ||
=Master Data Processing Scripts= | =Master Data Processing Scripts= | ||
Line 59: | Line 59: | ||
=Processing Reference= | =Processing Reference= | ||
Rosemount Manual | Rosemount Total Temperature Manual and Total Temperature Sensors Technical Report 5755 (TechicalReport5755.pdf). |
Latest revision as of 09:55, 3 April 2016
Rosemount Temperature Probe -- Aircraft Processing
Master Data Processing Scripts
process_all
Purpose
Select either Analog or CIP data from static and dynamic pressure measurements in the *.physical.* file.
Default
Analog data
Primitive Data Processing Scripts
process_raw
Purpose
Extracts analog data from SEA M300 data system file (*.sea) and creates the *.analog.raw file. Extracts Cloud Imaging Probes (CIP) housekeeping information from SEA M300 data system file(*.sea).
Required Input File
*.sea
Output File
*.analog.raw
*.housekeeping.cip.raw
analog2physical
Purpose
To convert analog measurements from engineering units (voltages) to physical units (i.e. degree C).
Required Input File
*.analog.*
Output File
*.physical.raw
convert_physical
Purpose
Uses total temperature, static pressure and dynamic pressure to correct for dynamic effect on the total temperature measurement to calculate air temperature.
Required Input File
*.physical.*
Output File
*.basic.raw
Processing Reference
Rosemount Total Temperature Manual and Total Temperature Sensors Technical Report 5755 (TechicalReport5755.pdf).