.rosemounttemp:M300: Difference between revisions

From ADPAA
Jump to navigation Jump to search
(Created page with "Page")
 
 
(7 intermediate revisions by 2 users not shown)
Line 1: Line 1:
Page
 
Rosemount Temperature Probe -- Aircraft Processing
 
=Master Data Processing Scripts=
===process_all===
''Purpose''
 
Select either Analog or CIP data from static and dynamic pressure measurements in the *.physical.* file.
 
''Default''
 
Analog data
 
=Primitive Data Processing Scripts=
===process_raw===
 
''Purpose''
 
Extracts analog data from SEA M300 data system file (*.sea) and creates the *.analog.raw file.  Extracts Cloud Imaging Probes (CIP) housekeeping information from SEA M300 data system file(*.sea).
 
''Required Input File''
 
<nowiki>*.sea</nowiki>
 
''Output File''
 
<nowiki>*.analog.raw</nowiki>
 
<nowiki>*.housekeeping.cip.raw</nowiki>
 
===analog2physical===
 
''Purpose''
 
To convert analog measurements from engineering units (voltages) to physical units (i.e. degree C).
 
''Required Input File''
 
<nowiki>*.analog.*</nowiki>
 
''Output File''
 
<nowiki>*.physical.raw</nowiki>
 
===convert_physical===
 
''Purpose''
 
Uses total temperature, static pressure and dynamic pressure to correct for dynamic effect on the total temperature measurement to calculate air temperature.
 
''Required Input File''
 
<nowiki>*.physical.*</nowiki>
 
''Output File''
 
<nowiki>*.basic.raw</nowiki>
 
=Processing Reference=
 
Rosemount Total Temperature Manual and Total Temperature Sensors Technical Report 5755 (TechicalReport5755.pdf).

Latest revision as of 09:55, 3 April 2016

Rosemount Temperature Probe -- Aircraft Processing

Master Data Processing Scripts

process_all

Purpose

Select either Analog or CIP data from static and dynamic pressure measurements in the *.physical.* file.

Default

Analog data

Primitive Data Processing Scripts

process_raw

Purpose

Extracts analog data from SEA M300 data system file (*.sea) and creates the *.analog.raw file. Extracts Cloud Imaging Probes (CIP) housekeeping information from SEA M300 data system file(*.sea).

Required Input File

*.sea

Output File

*.analog.raw

*.housekeeping.cip.raw

analog2physical

Purpose

To convert analog measurements from engineering units (voltages) to physical units (i.e. degree C).

Required Input File

*.analog.*

Output File

*.physical.raw

convert_physical

Purpose

Uses total temperature, static pressure and dynamic pressure to correct for dynamic effect on the total temperature measurement to calculate air temperature.

Required Input File

*.physical.*

Output File

*.basic.raw

Processing Reference

Rosemount Total Temperature Manual and Total Temperature Sensors Technical Report 5755 (TechicalReport5755.pdf).