.rosemounttemp:M300: Difference between revisions

From ADPAA
Jump to navigation Jump to search
No edit summary
 
(6 intermediate revisions by 2 users not shown)
Line 1: Line 1:
==process_raw==


'''Purpose'''
Rosemount Temperature Probe -- Aircraft Processing


Extracts *.physical.raw from SEA M300 data system file (*.sea)
=Master Data Processing Scripts=
===process_all===
''Purpose''


'''Required Input File'''
Select either Analog or CIP data from static and dynamic pressure measurements in the *.physical.* file.
 
''Default''
 
Analog data
 
=Primitive Data Processing Scripts=
===process_raw===
 
''Purpose''
 
Extracts analog data from SEA M300 data system file (*.sea) and creates the *.analog.raw file.  Extracts Cloud Imaging Probes (CIP) housekeeping information from SEA M300 data system file(*.sea).
 
''Required Input File''


<nowiki>*.sea</nowiki>
<nowiki>*.sea</nowiki>


'''Output File'''
''Output File''
 
<nowiki>*.analog.raw</nowiki>
 
<nowiki>*.housekeeping.cip.raw</nowiki>
 
===analog2physical===
 
''Purpose''
 
To convert analog measurements from engineering units (voltages) to physical units (i.e. degree C).
 
''Required Input File''
 
<nowiki>*.analog.*</nowiki>
 
''Output File''


<nowiki>*.physical.raw</nowiki>
<nowiki>*.physical.raw</nowiki>


==convert_physical==
===convert_physical===


'''Purpose'''
''Purpose''


Extracts static temperature from total temperature in *.physical.raw file and is corrected for dynamic temperature
Uses total temperature, static pressure and dynamic pressure to correct for dynamic effect on the total temperature measurement to calculate air temperature.


'''Required Input File'''
''Required Input File''


<nowiki>*.physical.raw</nowiki>
<nowiki>*.physical.*</nowiki>


'''Output File'''
''Output File''


<nowiki>*.basic.raw</nowiki>
<nowiki>*.basic.raw</nowiki>
=Processing Reference=
Rosemount Total Temperature Manual and Total Temperature Sensors Technical Report 5755 (TechicalReport5755.pdf).

Latest revision as of 09:55, 3 April 2016

Rosemount Temperature Probe -- Aircraft Processing

Master Data Processing Scripts

process_all

Purpose

Select either Analog or CIP data from static and dynamic pressure measurements in the *.physical.* file.

Default

Analog data

Primitive Data Processing Scripts

process_raw

Purpose

Extracts analog data from SEA M300 data system file (*.sea) and creates the *.analog.raw file. Extracts Cloud Imaging Probes (CIP) housekeeping information from SEA M300 data system file(*.sea).

Required Input File

*.sea

Output File

*.analog.raw

*.housekeeping.cip.raw

analog2physical

Purpose

To convert analog measurements from engineering units (voltages) to physical units (i.e. degree C).

Required Input File

*.analog.*

Output File

*.physical.raw

convert_physical

Purpose

Uses total temperature, static pressure and dynamic pressure to correct for dynamic effect on the total temperature measurement to calculate air temperature.

Required Input File

*.physical.*

Output File

*.basic.raw

Processing Reference

Rosemount Total Temperature Manual and Total Temperature Sensors Technical Report 5755 (TechicalReport5755.pdf).