Rosemount Temperature Probe (Aircraft Processing)
Primitive Data Processing Scripts
process_raw
Purpose
Extracts analog data from SEA M300 data system files (*.sea) and creates the *.analog.raw file.
Required Input File
*.sea
Output File
*.analog.raw
analog2physical
Purpose
To convert analog measurements from engineering units (voltages) to physical units (i.e. degree C).
Required Input File
*.analog.*
Output File
*.physical.*
convert_physical
Purpose
Uses total temperature, static pressure and dynamic pressure to correct for dynamic effect on the total temperature measurement to calculate air temperature.
Required Input File
*.physical.*
Output File
*.basic.raw
Processing Reference
Rosemount Manual